Kaspersky Unified Monitoring and Analysis Platform

Type 1c-log

18 June 2024

ID 244775

The 1c-log type is used to retrieve data from 1C application technology logs. Strings delimiter: \n. The connector accepts only the first line from a multi-line event record. This type of connector is available for Linux Agents.

When creating this type of connector, specify values for the following settings:

  • Basic settings tab:
    • Name (required)—a unique name for this type of resource. Must contain 1 to 128 Unicode characters.
    • Tenant (required)—name of the tenant that owns the resource.
    • Type (required)—connector type, 1c-log.
    • URL (required)—full path to the directory containing files that you need to interact with. For example, /var/log/1c/logs/.

      Limitations when using prefixes in file paths

    • Description—resource description: up to 4,000 Unicode characters.
  • Advanced settings tab:
    • Character encoding setting specifies character encoding. The default value is UTF-8.
    • Buffer size is the setting that lets you specify the size in bytes of the buffer for accumulating events in RAM before sending them for storage or for further processing.
      Default value: 1048576 bytes (1 MB).
      Possible values: positive integer less than or equal to 67108864 bytes (64 MB).
    • Poll interval, ms is the setting that lets you set the interval with which the connector re-reads the directory with files. The value is in milliseconds. The connector wait for specified time only if there are no changes in the file. If the file is continuously modified, and Poll interval = 5000 milliseconds, the 5-second interval for re-reading the files in the directory is not observed, and instead they are re-read continuously. If there are no changes in the file, the connector waits for 5 seconds. If 0 is set in the web interface, the default value of 700 ms is used.
    • Debug—a toggle switch that lets you specify whether resource logging must be enabled. By default, this toggle switch is in the Disabled position.

Connector operation diagram:

  1. All 1C technology log files are searched.

    Log file requirements:

    • Files with the LOG extension are created in the log directory (/var/log/1c/logs/ by default) within a subdirectory for each process.

      Example of a supported 1C technology log structure

    • Events are logged to a file for an hour; after that, the next log file is created.
    • The file names have the following format: <YY><MM><DD><HH>.log. For example, 22111418.log is a file created in 2022, in the 11th month, on the 14th at 18:00.
    • Each event starts with the event time in the following format: <mm>:<ss>.<microseconds>-<duration_in_microseconds>.
  2. The processed files are discarded.

    Information about processed files is stored in the file /<collector working directory>/1c_log_connector/state.json.

  3. Processing of the new events starts, and the event time is converted to the RFC3339 format.
  4. The next file in the queue is processed.

Connector limitations:

  • Installation of a collector with a 1c-log connector is not supported in a Windows operating system. To set up file transfers of 1C log files for processing by the KUMA collector:
    1. On the Windows server, grant read access over the network to the folder with the 1C log files.
    2. On the Linux server, mount the shared folder with the 1C log files on the Windows server (see the list of supported operating systems).
    3. On the Linux server, install the collector that you want to process 1C log files from the mounted shared folder.
  • Only the first line from a multi-line event record is processed.
  • The normalizer processes only the following types of events:
    • ADMIN
    • ATTN
    • CALL
    • CLSTR
    • CONN
    • DBMSSQL
    • DBMSSQLCONN
    • DBV8DBENG
    • EXCP
    • EXCPCNTX
    • HASP
    • LEAKS
    • LIC
    • MEM
    • PROC
    • SCALL
    • SCOM
    • SDBL
    • SESN
    • SINTEG
    • SRVC
    • TLOCK
    • TTIMEOUT
    • VRSREQUEST
    • VRSRESPONSE

Did you find this article helpful?